MOXA PT-G503-PHR-PTP
IEC 61850-3/62439-3 3-port full Gigabit managed redundancy boxes
- IEC 61850-3, IEEE 1613 (power substations) compliant
- IEC 62439-3 Clause 4 (PRP) and Clause 5 (HSR) compliant
- PRP/HSR Coupling and QuadBox functions supported
- Ethernet console reserved for local access ››Built-in MMS server, based on IEC 61850-90-4 switch modeling for power SCADA
- Hardware-based IEEE 1588v2 PTP supported
- Design ready for NERC CIP compliance system development
- Isolated redundant power inputs with universal 24/48 VDC or 110/220 VDC/VAC power supply range
- -40 to 85°C operating temperature range
Die Redundanz-Boxen (RedBoxes) der Serie PT-G503-PHR-PTP sind konform mit den neuesten standardisierten Redundanzprotokollen für industrielle Automationsnetzwerke gemäß IEC 62439-3 Clause 4 (Parallel Redundancy Protocol, PRP) und IEC 62439-3 Clause 5 (High-availability Seamless Redundancy, HSR). PRP/HSR gewährleistet die höchste Systemverfügbarkeit und Datenintegrität für betriebskritische Anwendungen in Umspannwerken und/oder Prozessautomationssystemen, die eine Redundanz mit einer Wiederherstellungszeit von null erfordern.
Die redundanten Protokolle Kopplung und QuadBox werden ebenfalls unterstützt. Bei Kopplung und QuadBox können HSR-Ringe miteinander verbunden werden, um das redundante Netzwerk vielseitiger einsetzbar zu machen. Die Serie PT-G503-PHR-PTP verfügt über drei 10/100/1000BaseT(X)- und 100/1000BaseSFP-Slot-Combo-Ports.
Ein Slot (INTERLINK-Port) ist für eine interne Verbindung mit einem SAN (Single Attached Node) vorgesehen. Die beiden anderen Ports (für LAN A und LAN B) dienen zur Kommunikation nach dem redundanten PRP/HSR-Protokoll. Mit diesem Full-Gigabit-Ethernet-Port-Konzept bietet die Serie PT-G503-PHR-PTP eine hohe Leistungsfähigkeit für PRP/HSR-Systeme.
Die Serie PT-G503-PHR-PTP arbeitet außerdem mit dem hardwarebasierten PTP gemäß IEEE 1588v2, wenn sie bei zeitkritischen Anwendungen im transparenten End-to-End-Einzelschritt-Clock-Modus betrieben wird, und verfügt über galvanisch getrennte redundante Versorgungsspannungseingänge mit Spannungsbereich von 24/48 VDC oder 110/220 VDC/VAC, um die Zuverlässigkeit der Stromversorgung zu erhöhen.
Technology
- Standards
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseX
Software Features
- Management
IPv4/IPv6, PRP/HSR, SNMPv1/v2c/v3, DHCP Client, BootP, SMTP, RARP, HTTP, Telnet, LLDP, Flow Control, Back Pressure Flow Control, SNMP Inform, Port Mirror, Fiber Check, Syslog, RMON
Filter
Multicast Filter Behavior
Redundancy Protocols
PRP/HSR, RSTP Transparent
Security
RADIUS, TACACS+, Trusted Access Control, Authentication Certificate (SSL Certificate, SSH Key Regenerate)
Time Management
SNTP, NTP Server/Client, IEEE 1588v2 PTP
Industrial Protocols
Modbus/TCP
MIB
IEC 62439-3 MIB
Power Substation
MMS
Interface
- Gigabit Ethernet
- +13 to +30 V for state “1”
- -30 to +3 V for state “0”
- Max. input current: 8 mA
3 x 10/100/1000BaseT(X) ports or 100/1000BaseSFP combo ports
Console Port
Ethernet console (10/100/1000 Mbps RJ45), USB-serial console (Type B connector)
Storage Port
USB storage (Type A connector for ABC-02-USB)
Alarm Contact 1 relay output with current carrying capacity of 1 A @ 24 VDC
Digital Inputs
1 input with the same ground, but electrically isolated from the electronics
Power Requirements
- Input Voltage
- WV: 24/48 VDC
- HV: 110/220 VDC/VAC
- WV: 18 to 72 VDC
- HV: 88 to 300 VDC, 85 to 264 VAC
- Max. 0.660/0.360 A @ 24/48 VDC
- Max. 0.150/0.080 A @ 110/220 VDC
- Max. 0.260/0.170 A @ 110/220 VAC
Operating Voltage
Input Current
Overload Current Protection
Present
Connection
5-pin terminal block
Reverse Polarity Protection
Present
Physical Characteristics
- Housing
Aluminum alloy
IP Rating
IP40 protection
Dimensions
80 x 160 x 110 mm (3.15 x 6.30 x 4.33 in)
Weight
1210 g (2.69 lb)
Installation
DIN-rail mounting
Environmental Limits
- Operating Temperature
-40 to 85°C (-40 to 185°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Standards and Certifications
- High Availability Automation Networks
IEC 62439-3
Safety
UL 508
EMI
FCC Part 15 Subpart B Class A, EN 55022 Class A
EMS
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 35 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8
IEC 61000-4-11
Rail Traffic
EN 50121-4
Electrical Substation
IEC 61850-3, IEEE 1613
MTBF (mean time between failures)
- Time
PT-G503-PHR-PTP-WV:440,857 hrs
PT-G503-PHR-PTP-HV:566,844 hrs
Standard
Telcordia TR/SR
Ordering Information
Available Modules | |
PT-G503-PHR-PTP-WV | IEC 61850-3 and IEC 62439-3 full Gigabit managed redundancy box, with 3 10/100/1000BaseT(X) ports or 100/1000Base SFP ports, 1 10/100/1000BaseT(X) Ethernet console port, 1 isolated dual power supply(24/48 VDC), -40 to 85°C operating temperature |
PT-G503-PHR-PTP-HV | IEC 61850-3 and IEC 62439-3 full Gigabit managed redundancy box, with 3 10/100/1000BaseT(X) ports or 100/1000Base SFP ports, 1 10/100/1000BaseT(X) Ethernet console port, 1 isolated dual power supply(88 to 300 VDC or 85 to 264 VAC), -40 to 85°C operating temperature |