MOXA TCF-142 Series

RS-232/422/485 to optical fiber media converters

MOXA TCF-142 Series
499_12293.png
499_8818.png
499_8819.png
499_8820.png
499_8821.png
499_25871.jpg
499_25872.jpg
499_25873.jpg
499_25874.jpg
499_25875.jpg
499_25876.jpg
  • EigenschaftenEigenschaften
  • BeschreibungBeschreibung
  • Weitere InformationenWeitere Informationen
  • PDFPDF
  • “Ring” and “Point- to-Point” transmission
  • Extends RS-232/422/485 transmission up to:
  • 40 km with single-mode—TCF-142-S
  • 5 km with multi-mode—TCF-142-M
  • Decreases signal interference
  • Protects against electrical interference and chemical corrosion
  • Supports baudrates up to 921.6 kbps
  • Wide temperature models available (-40 to 75°C)
Der TCF-142-Medienkonverter verfügt über einen mehrfachen Schnittstellenschaltkreis für serielle RS-232- oder RS-422/485-Schnittstellen und Multi-Mode- oder Single-Mode-Glasfaser. TCF-142-Konverter werden zur Erweiterung der seriellen Übertragung auf bis zu 5 km (TCF-142-M mit Multi-Mode-Glasfaser) oder bis zu 40 km (TCF-142-S mit Single-Mode-Glasfaser) verwendet. Der TCF-142 kann zur Konvertierung von RS-232- oder RS-422/485-Signalen verwendet werden (jedoch nicht gleichzeitig).

Automatische Baudratenerkennung

Der TCF-142 kann die serielle Baudrate automatisch erkennen. Dies ist eine sehr komfortable Funktion. Auch wenn sich die Baudrate eines Geräts ändert, wird das Signal dennoch ohne Datenverlust durch den Medienkonverter geleitet.

Ringbetrieb

Der TCF-142 kann zur Verbindung serieller Geräte zu einem Glasfaserring verwendet werden. Wenn Sie einen Ring bilden möchten, verbinden Sie den Tx-Port eines TCF-142 mit dem Rx-Port eines benachbarten Konverters. Nach der Einrichtung des Rings können Sie mithilfe der DIP-Schalter den TCF-142 im „Ringmodus“ konfigurieren. Sendet ein Knoten ein Signal, wird dieses im Ring weitergeleitet, bis es wieder zum Absender zurückgelangt und dort blockiert wird. Beim TCF-142 können Sie Glasfaserringe mit einem Gesamtumfang von bis zu 100 km einrichten.

Automatic Data Direction Control (ADDC®)

ADDC® ist eine patentierte Hardware-Datenflusslösung von Moxa für die RS-485-Datenrichtungssteuerung. ADDC® erkennt und steuert die RS-485-Datenrichtung automatisch, sodass das Handshaking-Signal nicht mehr benötigt wird.

ProdGrafik
Optical-Fiber Side

Fiber Connector
SC or ST

Fiber Cable Requirements

Ring Transmission
Half-duplex

Point-to-Point Transmission
Half-duplex or full-duplex


RS-232/422/485 Side

Connector
Terminal Block

RS-232 Signals
Tx, Rx, GND

RS-422 Signals
TxD+, TxD-, RxD+, RxD-, GND

RS-485-4w Signals
TxD+, TxD-, RxD+, RxD-, GND

RS-485-2w Signals
Data+, Data-, GND

Baudrate
50 bps to 921.6 kbps


Physical Characteristics

Housing
Metal

Dimensions
Without ears: 67 x 100 x 22 mm (2.64 x 3.94 x 0.87 in)
With ears: 90 x 100 x 22 mm (3.54 x 3.94 x 0.87 in)

Weight
320 g (0.71 lb)


Environmental Limits

Operating Temperature
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)

Storage Temperature
-40 to 75°C (-40 to 167°F)

Ambient Relative Humidity
5 to 95% (non-condensing)


Power Requirements

Input Voltage
12 to 48 VDC

Input Current
140 mA @ 12 VDC

Power Line Protection
1 kV Burst (EFT), EN61000-4-4
1 kV Surge, EN61000-4-5

Voltage Reversal Protection
Protects against V+/V- reversal

Overcurrent Protection
1.1 A (protects against two signals shorted together)


Standards and Certifications

Safety
UL 60950-1

EMC
EN 55022/24

EMI
CISPR 22, FCC Part 15B Class B

EMS
EN 61000-4-2 (ESD): Contact: 6 kV; Air: 8 kV
EN 61000-4-3 (RS): 80 MHz to 1 GHz: 10 V/m
EN 61000-4-4 (EFT): Power: 1 kV
EN 61000-4-5 (Surge): Power: 1 kV
EN 61000-4-6 (CS): 150 kHz to 80 MHz: 3 V/m
EN 61000-4-8 (PFMF)

Green Product
RoHS, CRoHS, WEEE


MTBF (mean time between failures)

Time
780,480 hrs

Standard
Telcordia (Bellcore), GB




Ordering Information
Available Models
TCF-142-M-SC RS-232/422/485 to multi-mode optical fiber media converter with fiber ring support and SC connector, 0 to 60°C operating temperature
TCF-142-M-ST RS-232/422/485 to multi-mode optical fiber media converter with fiber ring support and ST connector, 0 to 60°C operating temperature
TCF-142-S-SC RS-232/422/485 to single-mode optical fiber media converter with fiber ring support and SC connector, 0 to 60°C operating temperature
TCF-142-S-ST RS-232/422/485 to single-mode optical fiber media converter with fiber ring support and ST connector, 0 to 60°C operating temperature
TCF-142-M-SC-T RS-232/422/485 to multi-mode optical fiber media converter with fiber ring support and SC connector, -40 to 75°C operating temperature
TCF-142-M-ST-T RS-232/422/485 to multi-mode optical fiber media converter with fiber ring support and ST connector, -40 to 75°C operating temperature
TCF-142-S-SC-T RS-232/422/485 to single-mode optical fiber media converter with fiber ring support and SC connector, -40 to 75°C operating temperature
TCF-142-S-ST-T RS-232/422/485 to single-mode optical fiber media converter with fiber ring support and ST connector, -40 to 75°C operating temperature