MOXA TCC-120

Industrial RS-422/485 converter/repeater with 2 KV isolation protection

MOXA TCC-120
508_12288.png
508_8795.png
508_25836.jpg
508_25837.jpg
508_25838.jpg
508_25839.jpg
  • EigenschaftenEigenschaften
  • BeschreibungBeschreibung
  • Weitere InformationenWeitere Informationen
  • PDFPDF
  • Boost serial signal to extend transmission distance
  • Wall or DIN-Rail mounting
  • Terminal block for easy wiring
  • Power input from terminal block
  • DIP switch setting for built-in terminator (120 ohm)
  • Boost RS-422 or RS-485 signal, or convert RS-422 to RS-485
  • 2 kV isolation protection (TCC-120I)
Die Modelle TCC-120 und TCC-120I sind RS-422/485-Konverter/Repeaters zur Erweiterung der RS-422/485-Übertragungsentfernung. Beide Produkte bieten ein modernes industrielles Design mit Hutschienen-Montage, Klemmleistenverdrahtung und externen Stromklemmleisten. Außerdem unterstützt das Modell TCC-120I optische Isolation zum Schutz des Systems. Die Modelle TCC-120 und TCC-120I sind ideale RS-422/485-Konverter/Repeater für kritische industrielle Umgebungen.
ProdGrafik
Serial Communication

Connectors
Terminal Block on both ends

Baudrate
50 bps to 921.6 kbps

Signals
RS-422/485-4w: TxD+, TxD-, RxD+, RxD-
RS-485-2w: Data+, Data-

RS-485 Data Direction Control
ADDC® (automatic data direction control)

ESD Protection
15 kV for all signals

Optical Isolation
2 kV (TCC-120I only)


Physical Characteristics

Housing
Metal

Dimensions
67 x 100.4 x 22 mm (2.64 x 3.93 x 0.87 in)

Weight
148 ± 5 g


Environmental Limits

Operating Temperature
-20 to 60°C (-4 to 140°F)

Storage Temperature
-20 to 75°C (-4 to 167°F)

Ambient Relative Humidity
5 to 95% (non-condensing)


Power Requirements

Source of Power Input
Power input jack

Input Voltage
12 to 48 VDC

Power Consumption
TCC-120: 65 mA @ 12 V
TCC-120I: 180 mA @ 12 V

Voltage Reversal Protection
Protects against V+/V- reversal

Over Current Protection
Protects against two signals shorted together


Standards and Certifications

Safety
UL 60950-1

EMC
CE, FCC

EMI
FCC Part 15 Subpart B Class B

EMS
EN 61000-4-2 (ESD) Level 2,
EN 61000-4-3 (RS) Level 2,
EN 61000-4-4 (EFT) Level 2,
EN 61000-4-5 (Surge) Level 2,
EN 61000-4-6 (CS) Level 2,
EN 61000-4-8 (PFMF) Level 1

Green Product
RoHS, CRoHS, WEEE


MTBF (mean time between failures)

Time
1,949,025 hrs

Database
Telcordia (Bellcore), GB



Ordering Information

           Available Modules
TCC-120 RS-422/485 converter/repeater
TCC-120I RS-422/485 converter/repeater with Optical Isolation