MOXA CP-134U / CP-134U-I

SPHINX in Europa
CH
  • AT
  • BE
  • DK
  • FR
  • DE
  • IE
  • IT
  • NL
  • ES
  • SE
  • CH
  • UK
Produktgruppen > Multiport Serial Cards > MOXA CP-134U / CP-134U-I

MOXA CP-134U / CP-134U-I

4-port RS-422/485 smart Universal PCI serial boards with 2 KV isolation protection

MOXA CP-134U / CP-134U-I
553_12698.png
553_8454.png
  • EigenschaftenEigenschaften
  • BeschreibungBeschreibung
  • Weitere InformationenWeitere Informationen
  • PDFPDF
  • Over 700 kbps data throughput for top performance
  • 921.6 kbps maximum baudrate for super fast data transmission
  • ADDC® provides automatic data direction control for RS-485 signals
  • 128-byte FIFO and on-chip H/W, S/W flow control
  • Compatible with 3.3/5V PCI and PCI-X
  • Drivers provided for a broad selection of operating systems, including the latest Windows and Linux
  • 15 kV ESD protection on the board
  • Added bonus! Ports 1 and 2 support RS-232 and RS-422/485
  • Wide temperature model available for -40 to 85°C environments
Die Modelle CP-134U und CP-134U-I sind PCI-Boards mit vier Ports, für industrielle Automatisierungsanwendungen mit großen Entfernungen, mehreren Zugriffspunkten und PC-basierter Datenerfassung entwickelt wurden.

Auf dem Chip integriertes ADDCTM für präzise RS-485-Kommunikation

Die RS-485-Kommunikation erfordert präzise Zeitsteuerung zur Aktivierung/Deaktivierung des Leitungstreibers. Der Moxa Turbo Serial Engine™ Chip der CP-134U-Platine verfügt über integrierte ADDCTM, sodass RS-485 ebenso einfach zu verwenden ist wie RS-232.

RS-485-Multidrop für bis zu 31 Geräte in einer Entfernung von bis zu 1,2 km

Das CP-134U Universal PCI-Board verfügt über vier serielle RS-422/485-Ports, die jeweils Datenraten von bis zu 921,6 Kbps unterstützen. Im RS-485-Modus kann das Board bis zu 31 verkettete RS-485-Geräte in einem Bereich von 1,2 km verbinden. Bei RS-485-Kommunikation über große Entfernungen steht das Modell CP-134U-I mit optischer 2 KV-Isolierung zur Verfügung, um Schäden an den Geräten zu vermeiden.

Treiber für Windows, Linux und Unix

Moxa unterstützt auch weiterhin eine breite Palette von Betriebssystemen. Die CP-134U- und CP-134U-I-Platinen machen hierbei keine Ausnahme. Zuverlässige Windows COM- und Linux/Unix TTY-Treiber werden für alle Moxa Boards zur Verfügung gestellt. Außerdem werden weitere Betriebssysteme (z. B. WEPOS) für die umfassende Integration angeboten.

ProdGrafik

Hardware

Comm. Controller
MU860 (16C550C compatible)

Bus
32-bit Universal PCI

Connector
DB44 female


Serial Interface

Number of Ports
4

Serial Standards
2 x RS-232/422/485, 2 x RS-422/485

Max. No. of Boards per PC
4


Serial Line Protection

ESD Protection
15 kV on the board

Electrical isolation
2 kV (CP-134U-I configured for RS-422/485 only)


Performance

Baudrate
50 bps to 921.6 kbps


Serial Communication Parameters

Data Bits
5, 6, 7, 8

Stop Bits
1, 1.5, 2

Parity
None, Even, Odd, Space, Mark

Flow Control
RTS/CTS, XON/XOFF

I/O Address
Assigned by BIOS

IRQ
Assigned by BIOS


Serial Signals

RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

RS-422
TxD+(B), TxD-(A), RxD+(B), RxD-(A), RTS+(B), RTS-(A), CTS+(B), CTS-(A), GND

RS-485-4w
TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND

RS-485-2w
Data+(B), Data-(A), GND


Operating Systems

Windows Real COM Drivers
Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1 (x86/x64),
Windows 2008 R2/2012/2012 R2 (x64), DOS, Windows Embedded CE 5.0/6.0, Windows XP Embedded

Fixed TTY Drivers
QNX 6, SCO OpenServer, UnixWare 7, Solaris 10, FreeBSD

Linux Real TTY Drivers
Linux 2.4.x, 2.6.x


Physical Characteristics

Dimensions
CP-134U: 82.5 x 120 mm (3.24 x 4.72 in)
CP-134U-I: 115 x 120 mm (4.52 x 4.72 in)


Environmental Limits

Operating Temperature
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F)

Storage Temperature
-40 to 85°C (-40 to 185°F)

Ambient Relative Humidity
5 to 95% (non-condensing)

Altitude
Up to 2000 m
Note Please contact us if you require products guaranteed to function properly at higher altitudes.


Standards and Certifications

EMC
CE, FCC

EMI
EN 55022, FCC Part 15 Subpart B Class B

EMS
EN 55024, IEC 61000-4-2, IEC 61000-4-3

Green Product
RoHS, CRoHS, WEEE


MTBF (mean time between failures)

Time
480,209 hrs

Database
Telcordia (Bellcore), GB


Power Requirements

Power Consumption
CP-134U: 180 mA @ +5 V
CP-134U-I: 850 mA @ +5 V




Ordering Information

CP-134U
    4-port RS-422/485 Universal PCI serial board, 0 to 55°C operating temperature

CP-134U-DB9M
    4-port RS-422/485 Universal PCI serial board, 0 to 55°C operating temperature (includes DB9 male cable)

CP-134U-DB25M
    4-port RS-422/485 Universal PCI serial board, 0 to 55°C operating temperature (includes DB25 male cable)

CP-134U-I
    4-port RS-422/485 Universal PCI serial board with optical isolation, 0 to 55°C operating temperature

CP-134U-I-DB9M
    4-port RS-422/485 Universal PCI serial board with optical isolation, 0 to 55°C operating temperature (includes DB9 male cable)

CP-134U-I-DB25M
    4-port RS-422/485 Universal PCI serial board with optical isolation, 0 to 55°C operating temperature (includes DB25 male cable)

CP-134U-T
    4-port RS-422/485 Universal PCI serial board, -40 to 85°C operating temperature

CP-134U-I-T
    4-port RS-422/485 Universal PCI serial board with optical isolation, -40 to 85°C operating temperature